{"product_id":"0-75kw-frequency-converter-220v-single-phase-380v-3-phase-input-variable-frequency-inverter","title":"0.75KW Frequency Converter 220V Single Phase\/380V 3 Phase Input Variable Frequency Inverter","description":"\u003cdiv\u003e\n\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 780px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.75KW\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e220V or 380V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput frequency range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.01-400Hz The maximum frequency can be set arbitrarily between 25.00-400.0Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003esingle phase: 220V ± 15%; three phase: 380V ± 15%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e50-60Hz ± 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eControl mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003efull digital space voltage vector SVPWM algorithm; carrier frequency 1-12 KHz continuously adjustable.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eStarting frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.00- 25.00Hz can be set arbitrarily\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eOutput frequency resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.01Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eFrequency setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.01Hz:\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eAnalog input (external terminal) setting: 1% of the highest frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eV\/F characteristics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003elinear VF; base frequency can be set freely between 25.00 and 400.0 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eTorque compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003elinear torque compensation mode, compensation voltage range: 0-30%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eOverload capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e150% rated current 1 minute; 180%, rated current 2 seconds.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eStop mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003edeceleration stop \/ free stop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003eAcceleration and deceleration time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: 16px;\"\u003e0.1-6000 seconds (acceleration, deceleration can be set separately)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e-- This product is a high performance frequency converter, the power is \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e1.5KW\u003c\/span\u003e\u003c\/strong\u003e, the input is three-phase \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e380V\/50HZ\u003c\/span\u003e\u003c\/strong\u003e, the output is three-phase \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e380V\/ 0-400HZ\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e-- Input end is connected to \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eR S T,\u003c\/span\u003e\u003c\/strong\u003e output end is connected to \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eU V W \u003c\/span\u003e\u003c\/strong\u003emotor.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 16px;\"\u003e-- Widely used in: pump control flow, constant pressure water supply, engraving machine, printing machinery, packaging equipment, fan speed and other industries.\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 16px;\"\u003e-- Widely used in power electronics and transmission industry at home and abroad, energy saving transformation, used in power, textile and chemical fiber, building materials, petroleum, chemical, metallurgy, municipal, paper, food and beverage, to-bacco and other industries and public works (central air conditioning, water supply, water treatment, elevators, etc.).\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eWiring Instructions, Danger Tips:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e1. Before wiring, please confirm that the input power has been cut off.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eThere is a risk of electric shock and fire.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e2. Wiring work must be performed by an electrical engineering professional.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eThere is a risk of electric shock and fire.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e3. The grounding terminal must be reliably grounded.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cspan style=\"font-size: 16px;\"\u003eThere is a risk of electric shock and fire.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e4. After the emergency stop terminal is connected, be sure to check if its action is valid.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eThere is a danger of injury. (The wiring responsibility is borne by the user)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e5. Do not touch the output terminal directly. Do not connect the output terminals of the inverter to the housing, and do not short-circuit the output terminals.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e There is a risk of electric shock and short circuit.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e\u003cbr\u003e1. Please confirm whether the AC main circuit power supply and the rated voltage of the inverter are consistent. \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eThere is a risk of injury and fire.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e2. Do not perform voltage withstand test on the inverter. \u003cspan style=\"color: rgb(178, 34, 34);\"\u003e\u003cstrong\u003eCan cause damage to semiconductor components, etc.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e3. Connect the brake resistor or brake unit according to the wiring diagram. \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eThere is a danger of fire.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e4. Tighten the terminal with a screwdriver of the specified torque. \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eThere is a danger of fire.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e5. Do not connect the input power cable to the output U.V.W terminal. The voltage is applied to the output terminals, which \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003ecan cause internal damage to the inverter.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e6. Do not connect the phase shift capacitor to the output loop. \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eThis can cause internal damage to the inverter.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e7. Do not connect the electromagnetic switch or electromagnetic contactor to the output circuit. \u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003eWhen the inverter is running with load, the inrush current generated by the action of the electromagnetic switch and the electromagnetic contactor will cause the overcurrent protection circuit of the inverter to operate.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eProduct protection features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e-- After the inverter has abnormal conditions, the protection circuit and the fault output relay are activated, and the fault is displayed and stopped. Please find the cause of the fault and the corresponding countermeasures, and then solve the fault and then run. The inverter has over current. Intelligent power module protection, under voltage protection, over voltage protection, over temperature protection, overload protection.\u003cstrong\u003e\u003cspan style=\"color: rgb(178, 34, 34);\"\u003e (Please refer to the manual for details on the product usage and parameter introduction)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003cbr\u003e1 x Inverter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/BE\/E5\/4522f437-575a-459a-8e5e-ca8588541ca0.jpg\"\u003e\u003c\/div\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/E7\/7D\/7ed8433e-ec0e-4116-9383-65e51fc57786.jpg\"\u003e\u003c\/div\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/D8\/CB\/163021eb-5d02-4670-8858-73235985fc04.jpg\"\u003e\u003c\/div\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/55\/38\/311210af-fd65-44f2-bccb-39c4cbb8c6a9.jpg\"\u003e\u003c\/div\u003e","brand":"Electronic Pro","offers":[{"title":"Voltage 380V","offer_id":29526831267884,"sku":"1453045","price":5588.45,"currency_code":"ZAR","in_stock":false},{"title":"Voltage 220V","offer_id":29526831300652,"sku":null,"price":7088.45,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/4522f437-575a-459a-8e5e-ca8588541ca0.jpg?v=1583835502","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/0-75kw-frequency-converter-220v-single-phase-380v-3-phase-input-variable-frequency-inverter","provider":"Electronic Pro ","version":"1.0","type":"link"}