{"product_id":"600w-digital-control-dc-dc-adjustable-step-up-module-constant-voltage-current-solar-charging","title":"600W Digital Control DC-DC Adjustable Step Up Module Constant Voltage Current Solar Charging","description":"\u003cstrong\u003e600W Digital Control DC-DC Adjustable Step Up Module Constant Voltage Current Solar Charging\u003cbr\u003e\u003cbr\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e1. 600W digital control DC-DC adjustable step-up module is a full digital display programmable step-up module, it has the advantages of small size, high power, high\u003cbr\u003e     efficiency and stable operation.\u003cbr\u003e2. Use advanced microprocessor control, voltage and current has precise adjustment button, can achieve constant voltage and constant current output.\u003cbr\u003e3. With four 8-bit LED digital tube, can display real time output voltage and current.\u003cbr\u003e4. With working status indicator, you can check the real time status.\u003cbr\u003e5. With automatic output function after power, can be opened or closed according to need.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e1. Use advanced microprocessor, can be precisely regulate output voltage and current.\u003cbr\u003e2. With 4 high brightness LED digital tube, can display the output voltage, current, capacity and time.\u003cbr\u003e3. Support setting automatic output after power.\u003cbr\u003e4. High-quality power devices with peripherals precision amplifier to constitute CV and CC loop, which greatly improves the performance of the module.\u003cbr\u003e5. With two 1mm double-wire winding large current inductor, use two 1000uF\/63V electrolytic capacitor to input and three 470uF\/100V electrolytic capacitor to output.\u003cbr\u003e6. All-digital display, easy to use.\u003cbr\u003e7. Support constant voltage, constant current output.\u003cbr\u003e8. With working status indicators, which are OUT for output, CV for constant voltage, CC for constant current, can check the real time status.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eParameter:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 500px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e6~60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax input current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax input power\u003c\/td\u003e\n\u003ctd\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage range\u003c\/td\u003e\n\u003ctd\u003e6~90V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current range\u003c\/td\u003e\n\u003ctd\u003e0~9.99A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage adjust \/ display  resolution\u003c\/td\u003e\n\u003ctd\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent adjust \/ display  resolution\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ripple\u003c\/td\u003e\n\u003ctd\u003e≤50mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit protection\u003c\/td\u003e\n\u003ctd\u003e15A car fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring mode\u003c\/td\u003e\n\u003ctd\u003e8500 terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L*W*H)\u003c\/td\u003e\n\u003ctd\u003e104*60*44 (mm)                            \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e295g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cstrong\u003eHow to use:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e1.\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e Setting\u003c\/span\u003e \u003cspan\u003evoltage and current values\u003cbr\u003e     Default display after power-on is the voltage setpoint, press the \"SET\" button to switch to the current or voltage value.\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e2.\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e Start\u003c\/span\u003e \u003cspan\u003eOutput\u003cbr\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003eAfter setting\u003c\/span\u003e \u003cspan\u003evoltage and current values\u003c\/span\u003e\u003cspan\u003e, press the\u003c\/span\u003e \u003cspan\u003e\"OK\"\u003c\/span\u003e \u003cspan\u003ebutton to\u003c\/span\u003e \u003cspan\u003eoutput\u003c\/span\u003e\u003cspan\u003e.\u003cbr\u003e\u003cbr\u003e3. Turn off output\u003cbr\u003e     Under \u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003eoutput\u003c\/span\u003e \u003cspan\u003estate\u003c\/span\u003e\u003cspan\u003e,\u003c\/span\u003e \u003cspan\u003epress the\u003c\/span\u003e \u003cspan\u003e\"SET\"\u003c\/span\u003e \u003cspan\u003ebutton\u003c\/span\u003e \u003cspan\u003eto turn off\u003c\/span\u003e \u003cspan\u003ethe output\u003c\/span\u003e\u003cspan\u003e.\u003cbr\u003e\u003cbr\u003e4. \u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e \u003cspan\u003eoutput function    \u003cbr\u003e     Automatic output function open:\u003cbr\u003e     Long press \"SET\" button to enter the parameter setting page, click the \"UP\" button to adjust to \"-F2-\" option, then click the \"OK\" button, digital tube display \"Yo-0\", click \"UP\" button, the display switches to \"Yo-1\", and finally click\" OK \"button to save the settings.\u003cbr\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e     Automatic output function close:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e     Long press \"SET\" button to enter the parameter setting page, click the \"UP\" button to adjust to \"-F2-\" option, then click the \"OK\" button, digital tube display \"Yo-1\", click \"UP\" button, the display switches to \"Yo-0\", and finally click\" OK \"button to save the settings.\u003cbr\u003e\u003cbr\u003e5. \u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003eDisplay output\u003c\/span\u003e \u003cspan\u003ecapacity \/\u003c\/span\u003e \u003cspan\u003etime\u003cbr\u003e     Under the current display state, long press the “OK” button to display 0.00A, displayed value at this time is capacity value.\u003cbr\u003e     Under the voltage display state, long press the “OK” button to display 0.00H, displayed value at this time is time value.\u003cbr\u003e\u003cbr\u003e6. \u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003eParameters save\u003c\/span\u003e \/ \u003cspan\u003erecall\u003cbr\u003e      Parameters save:\u003cbr\u003e      Long press \"SET\" button to enter the parameter setting page, click the \"UP\" \/ \"DOWN\" button to adjust to \"-F0-\" option, then click the \"OK\" button, digital tube display \"Sn-0\", click \"UP\" \/ \"DOWN\" button to change the address, and finally click\" OK \"button to save the settings to the corresponding address bits.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e      Parameters\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e\u003cspan\u003e\u003cspan class=\"short_text\" id=\"result_box\" lang=\"en\"\u003e \u003cspan\u003erecall:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e      Long press \"SET\" button to enter the parameter setting page, click the \"UP\" \/ \"DOWN\" button to adjust to \"-F1-\" option, then click the \"OK\" button, digital tube display \"Lo-0\", click \"UP\" \/ \"DOWN\" button to change the address, and finally click\" OK \"button to recall the settings to the corresponding address bits.\u003cbr\u003e      There are 0~9 ten address bits, default to output 0 address bit data when power on.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePackage included:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e1 x Module\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.banggood.com\/images\/oaupload\/banggood\/images\/6F\/3B\/669b86aa-4d61-43b2-a899-b07a52476341.jpg\" style=\"\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.banggood.com\/images\/oaupload\/banggood\/images\/6F\/3B\/0ac805e4-bb0f-48a2-9fe4-7461ea8097aa.jpg\" style=\"\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.banggood.com\/images\/oaupload\/banggood\/images\/6F\/3B\/779bab65-8da2-47c8-be2b-08152c7ddc46.jpg\" style=\"\"\u003e","brand":"Shopify","offers":[{"title":"Default Title","offer_id":14147602186284,"sku":"1082316","price":879.56,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/669b86aa-4d61-43b2-a899-b07a52476341_df1b0e2a-3246-49c5-b402-eefa0e2b2cd7.jpg?v=1586880411","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/600w-digital-control-dc-dc-adjustable-step-up-module-constant-voltage-current-solar-charging","provider":"Electronic Pro ","version":"1.0","type":"link"}