{"product_id":"daniu-dc-0-500v-4bit-voltage-current-capacity-power-temp-meter-oled-multifunction-dc-electric-parameter-tester","title":"DANIU DC 0-500V 4Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester","description":"\u003cdiv\u003e\n\u003cspan style=\"color:#ff0000;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eType 1:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e DC Parameter Meter+\u003c\/span\u003e\u003cspan style=\"font-size:14px;\"\u003e100V \u003c\/span\u003e \u003cspan style=\"font-size:14px;\"\u003e20A out shunt\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eType 2: \u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003eDC Parameter Meter+\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e100V \u003c\/span\u003e  \u003cspan style=\"font-size:14px;\"\u003e50A out shunt\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eType 3: \u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003eDC Parameter Meter+\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e100V \u003c\/span\u003e \u003cspan style=\"font-size:14px;\"\u003e100A out shunt\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eReminder:\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eThe photo is used to demonstrate the working principle and appearance of the product. So we chose one of the parameters to take photos, showing that the resolution can not correspond to all specifications. The corresponding product's resolution is based on the number in the webpage introduction.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eTechnical parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eVoltage meter range: 00.00-99.99V  \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eCurrent meter range: Purchase choice\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMeasurement power: 0.000W-150KW [decimal point and unit automatically adjusted according to actual results]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eReal time power: 0.000AH-999.9AH [decimal point automatically adjusted according to actual results]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAccumulative energy:  0.000AH-99999AH [decimal point automatically adjusted according to actual results]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eCumulative watt time: 0.000WH-99999WH [decimal point automatically adjusted according to actual results]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTemp measurement: -15.0 degree to 65 degrees [resolution 0.1 degrees]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTime shows: 0-99 hours and 59 minutes [Load timing]\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAutomatic memory: 1 This time of electricity, 2 Add electricity many times. 3 Multiple additive energy\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInternal resistance of the voltmeter: 400KΩ\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInternal resistance of the ammeter:1A0.1Ω  1A25mΩ  5A10mΩ 10A5mΩ  30A2.5mΩ  50A1.5mΩ  100A0.75mΩ  200A0.375mΩ \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking voltage: DC5-12V  *1\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMeasurement accuracy: 0.2%\u003cfont color=\"#ff0000\"\u003e(\u003c\/font\u003e+\/-2\u003cfont color=\"#ff0000\"\u003e)\u003c\/font\u003e*2\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOperating temperatur: -10?�~60??nbsp;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking current: \u0026lt;15mA\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRefresh rate: 2 times\/second\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eCommunication function: provide TTL interface output data.3.3V5V compatible.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eDisplay mode: 0.96 OLED \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOverall dimensions: 48MM*29MM*21MM(L*W*H)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOpening size: 45.5mm*26.5mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eLead wire length: 13CM\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e    *1:The instrument can work in dc4-28v, but it will be hot when it is above 15V and reduce the accuracy and life. Please use 5-15V power supply.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e    *2:Error calculation method, the percentage of maximum range, plus the number in brackets\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/61\/6F\/b07bed5d-65b2-481c-8e4e-113dc5e873a2.jpg\" style=\"width: 691px; height: 634px;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/AC\/AB\/0b01cc4b-9a0b-4299-982a-3910eb141ca3.jpg\" style=\"width: 750px; height: 304px;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eVoltage: Voltage display\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eCurrent: Current display\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003ePower: Power display\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eCapacity: Capacity shows that the result of the last measurement is displayed first every time the power is connected. When this time exceeds 1mAH, it begins to be recalculated.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eTemp: PCB temperature measurement, about two degrees higher than room temperature\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eCumulative capacity: The result of the accumulative amount of electricity  for all measurements, If it is not cleared, it will always be accumulated.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eCumulative watt hour: The results of the accumulative energy of all measurements.If it is not cleared, it will always be accumulated.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTime:Load time\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eAlarm switch : This function is only for professional use.Used to make an instrument output a voltage signal and to control other devices.  \u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen the set is \u003con\u003e, If the voltage or current alarm condition realized, the output is 3.3V.  Otherwise output 0V\u003c\/on\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen the set is\u003coff\u003e, the output voltage is always 0V\u003c\/off\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eLimitch switching: This function is only for professional use.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen set to \u003cc.vo\u003e,Turn the operation channel into a voltage.\u003c\/c.vo\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen set to \u003cc.cu\u003e,Turn the operation channel into a current\u003c\/c.cu\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eHigh:This function is only for professional use.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e             Limitch switching=C.VO   The value shown here is the upper limit of the voltage.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e             Limitch switching=C.CU   The value shown here is the upper limit of the current.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eDown:This function is only for professional use.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e             Limitch switching=C.VO   The value shown here is the Lower limit of the voltage.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e             Limitch switching=C.CU   The value shown here is the Lower limit of the current\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eVery important hint: the default is 0 when the factory is out. To set up [Down], it is necessary to set up [High]. only when [Down] is less than [High], and the data will be saved successfully.\u003c\/span\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eKey use method:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThe instrument is designed with single key and can realize various operations.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e        A: In the normal interface, the length is 3 seconds into the adjustment state. The selected adjustment items will flicker. In this state, click the button to switch back and forth in the adjustment items. When selected: real time electricity, accumulating electricity, accumulating power, double click the button to realize the zero operation. When the alarm switch is selected, the channel switches, double click switch when the channel switches. When selected: upper and lower values, double click to enter data adjustment. In adjustment state, press 3 seconds to exit.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e        B: under normal interface, double click the button (2 times in short time), enter the calibration interface. It can calibrate the voltage, current, and zero point. The adjustment range is +\/-50%. When the parameters flicker, double click, enter the position adjustment (underline below the corresponding number), click the cycle to change the number, double click, change the adjustment position, and press the exit boundary. \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/EE\/06\/d21a712d-6651-4aaf-ab60-85e54aea1d4b.jpg\"\u003e\u003c\/div\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSupplement: this interface can also set alarm output mode. This function is very practical.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e     OUT:TUNR [alarm level changes with alarm status changes]\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003e     OUT:HOLD [alarm level lock, when the alarm occurs, output high level, even if the alarm conditions disappear, the output level remains, until a key to restore the low level]\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eWiring method:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThere are two sets of lines\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThree of the finer  A: groups,\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTwo thick B: group,\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eGroup A:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eblack wire: power supply negative pole\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRed wire: power supply positive. Warning: the maximum can only be connected to 28V, more than damage\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eYellow wire: connected to the positive electrode needed to measure voltage\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eGroup B:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eblack wire: the negative electrode of the tested power supply\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRed wire: the negative electrode of the load to be measured. Warning: not connected to the power supply positive pole, otherwise burned\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/0A\/02\/0da6b1ea-fa06-459d-b7a3-44764326fb78.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/B8\/F3\/007c83c7-e424-4df2-be6d-8c049be1e8e6.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"http:\/\/myosuploads3.banggood.com\/products\/20190513\/20190513014310BY62.rar\" target=\"_blank\"\u003e\u003cspan style=\"color:#ff0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003e?�Link for BY62 monitoring software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"http:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/17\/BF\/b3a51195-f549-4373-917b-5ca2127b8228.jpg\" style=\"width: 902px; height: 1432px;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOrdinary users only need to plug a USB-TTL line into the computer, and the corresponding DNG, TX, RX table head connected, open our software, you can automatically connect, without any settings.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e This protocol is for professional programmers only, for example, to achieve multi-online, other equipment interoperability. Ordinary users do not need to read.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eFirst.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e       device data output mode.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eBaud rate: 19200 check digit: NONE data bits: 8 stop bits: 1\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eEach output will output a set of device information consisting of 54 bytes.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e   Example: FA FC 1F 04 00 01 00 70 00 01 00 01 03 79 00 01 00 00 00 14 00 01 00 00 01 23 00 \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e            00 00 25 00 02 00 00 00 A8 00 02 00 00 00 01 00 00 00 00 FF 00 00 00 00 13 01 3F \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e   Position: 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e            28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e01 02: fixed to FA FC, data group start sign.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e03 04: voltage data (ignoring decimal point) =03*256+04;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e05 06: voltage decimal point. For example, 03*256+04=3000,05*256+06=3, the actual voltage is 300.0V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e07 08: current data (ignore decimal point)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e09 10: current decimal point position\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e11 12: current unit.11*256+12=1, when the current unit is A, when equal to 0, the unit is mA.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e13 14: power data (ignore decimal point)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e15 16: power decimal point position.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e17 18: power unit. Equal to 1 indicates that the unit is KW, equal to 0, indicating that the unit is W.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e19 20: real time capacity data (ignoring decimal point)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e21 22: real-time capacity decimal position\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e23 24: Real-time capacity content. When equal to 1, the content is the current upper capacitance value. When equal to 0, the content is the last power-down capacity value.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e25 26: temperature. Variable is int type. It can represent negative temperature.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e27 28 29 30: cumulative capacity value, variable Unsigned long type.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e31 32: cumulative capacity decimal position\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e33 34 35 36: accumulates tile time value, the variable is Unsigned long type.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e37 38: accumulating tile decimal point position\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e39 40: running time. The unit is minute.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e41 42: carried state. Equal to 1 indicates current value is not 0. equal to 0, indicating current value is 0.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e43: alarm switch. Alarm function is opened when the alarm is equal to 1. When the alarm function is equal to 0, the alarm function is turned off.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e44: upper and lower bound parameters. When equal to 1, the upper and lower bound values are displayed as voltage values. When equal to 0, the upper and lower values are displayed as current values.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e45 the upper limit of 46: shows.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e47 48: lower value display.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e49 50: Device Adjustment Item Number. 0 - Device Processing Normal Standby State. 1 - Select Real Time Capacity 2 - Select Total Capacity 3 - Select Total Watt Time 4 - Select Alarm Setting 5 - Select Voltage Current (Upper and Lower Limits) Switch\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e6 - Check the upper limit 7 - Check the upper limit 8 - Check the upper limit 10 - Check the upper limit 10 - Check the upper limit 10 - Check the lower limit 15 - Check the lower limit\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e18- select lower limit ten bits 22- select lower limit 100 bits.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e51: retained not used\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e52: check bit. All data correlation from 1 to 51. Rounding off carry. Can be used to detect data transmission error.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e53: Device Data Output Mode. 0 - Indicates Device Stop Output Data. 1 - Indicates Device in Single Output Mode 2 - Indicates Device Processing Continuous Output Mode\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e54: device address.0-63 has 64 addresses. The factory acquiescence can be used for identification when it is 00 parallel machines.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eExplain:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eInstrument output data will output measurement data, equipment adjustment status, equipment information. According to the need to filter selected useful information from their own.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTwo. \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eHow to issue instructions to equipment\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAll instructions start with 7E5F.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. the action instructions for sending keys to the device:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePractical example: 7E 5F C5 02\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSerial number:     01 02 03 04\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e01 02: identifies the head 03: device address +0xC0 04: action type 2- click 3- double click 4- long Click\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. issuing instructions for modifying addresses to the equipment:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePractical example: 7E 5F C5 A2\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSerial number:     01 02 03 04\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e01 02: identifies the head 03: device address +0xC0 04: the new device address +0x80. takes effect immediately.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. issuing instructions to modify the output mode to the device:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePractical example: 7E 5F C5 40\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSerial number:     01 02 03 04\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e01 02:Identification Header 03:Device Address+0xC0 04:Instruction Code 40-Device Stop Output 41-Single Output 42-Continuous Output\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. issue mandatory instructions to the device:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePractical example: 7E 5F 8A\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSerial number:     01 02 03\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e01 02:Identity Header 03:Instruction Code 8A-Unconditionally Stop Output 8B-Unconditionally Single Output A Group of Data This command ignores the device address and can be used to view the device address when forgetting that the device address is out of control.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAttachment: the data are all 16 hexadecimal, just for the convenience of explanation, there is no space in actual data.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x DC Parameter Meter\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eDetails Pictures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/9B\/AA\/d55fb4e1-e48c-4b32-b5a3-7453def03901.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/64\/1B\/2ec91caa-2b00-4796-b5f7-9ce735815c39.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/E8\/F6\/514e408a-1e05-4ee4-a724-c717ab23f239.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/4D\/AE\/c04cb5a2-79bc-404e-836a-40afc73a1e1c.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/B9\/86\/42753371-fc9f-4fca-a1d3-547b30b23bcb.jpg\"\u003e\n\u003c\/div\u003e","brand":"Shopify","offers":[{"title":"1","offer_id":29606083231788,"sku":"1475988","price":698.8,"currency_code":"ZAR","in_stock":true},{"title":"2","offer_id":29606083264556,"sku":null,"price":698.8,"currency_code":"ZAR","in_stock":true},{"title":"3","offer_id":29606083297324,"sku":null,"price":875.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/d55fb4e1-e48c-4b32-b5a3-7453def03901_1083a05b-908a-44ab-8a04-c54700f14e07.jpg?v=1583828110","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/daniu-dc-0-500v-4bit-voltage-current-capacity-power-temp-meter-oled-multifunction-dc-electric-parameter-tester","provider":"Electronic Pro ","version":"1.0","type":"link"}