{"product_id":"dc-6v-to-30v-one-way-relay-module-delay-power-off-disconnection-trigger-delay-cycle-timer","title":"DC 6V To 30V One Way Relay Module Delay Power Off Disconnection Trigger Delay Cycle Timer","description":"\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eParameters:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOperating voltage: DC 6V-30V (supports micro USB 5V)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTrigger signal source: high-level trigger (3V-24V) signal and systematically improve the system's anti-interference ability (also short-circuit altogether)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOutput capability: can control equipment that within DC 30V 5A or AC 220V 5A\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eStatic current: 20mA\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking current: 50mA\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eService life: more than 100,000 times\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking temperature: -40°C to 85°C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSize: 6.2*3.8*1.7cm (length*width*height)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eRelay enable mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. ON: the relay is allowed to turn on during the OP conduction time;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. OFF: the relay is disabled and always closed.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, and then return to the main interface. (this function is an emergency stop function, one-touch disconnected relay)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eSleep mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. C-P sleep mode: no operation within five minutes, the digital tube automatically shuts off the display and the program runs normally;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. O-d normal mode: the digital tube is always on display;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. Press and hold the STOP button for 2 seconds and release it to switch between the C-P and O-d states. The current state will flash, and then return to the main interface.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eOperating mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP1: after the signal is triggered, the relay turns on the OP time and then turns off; during the OP time, the following operation\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.1: signal is invalid again\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.2: signal triggered again\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.3: the signal triggers a reset again, the relay opens, and the timer stops.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP2: for the trigger signal, after the relay is turned off for CL time, the relay turns on the OP time. After the timing is completed, the relay is turned off;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP3.1: for the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, and then it circulates the above-mentioned action. In the cycle, the signal is given again, the relay is disconnected, and the time is stopped; the number of loops (LOP) can be set;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP3.2: after the power is turned on, no trigger signal is needed. The relay turns on the OP time, the relay turns off the CL time, and the above action is repeated. The loop number (LOP) can be set.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP4: signal hold function if there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is turned off after the timer OP; during the timer, there is another signal and the timer is cleared.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eHow to set parameters:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. First determine the relay operating mode;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), and then enter the main interface,) \"press and hold the SET button for 2 seconds to release \"enter the mode selection interface, select the mode to be set (P1.1~P-4) by pressing the UP and DOWN keys;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. After selecting the mode to be set (for example, P3.2), short-press the SET button to set the corresponding parameter, then the parameter to be set will blink (OP conduction time, CL disconnection time, LOP cycle times (\"-- - \"on behalf of infinite number of cycles)), through UP, DOWN adjust the parameter value, support long press (fast increase or decrease) and short press (increase or decrease 1 unit); after setting the parameter value, press STOP key shortly To select the decimal point position, select the time range (the corresponding time 0.1 seconds ~ 999 minutes); short press the SET button to set the next parameter of the current mode, the process is the same as above;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and release it. The currently set mode will flash, then return to the main interface, and set the parameters successfully.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMain interface: \"000\" (no decimal point) is displayed when the relay is not working. The relay is in working state with a decimal point. It is very clear!\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMode selection interface: long press the SET button to enter, after the setting is completed, long press the SET button to exit, return to the main interface\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThe relay output is a passive contact and has no live output to control the on-off of a line.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003ePackage included:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 X One way relay module\u003c\/span\u003e\u003c\/div\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/01\/D1\/dfbd2fa0-edad-4277-b9c5-0fbef70acce1.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/F5\/08\/8f9aae27-4f40-401a-83e0-4535287e3a4d.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/2A\/E8\/06c56f6b-4e96-4c87-b8c5-65c363de1b15.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/3F\/64\/ac375a75-a84f-4f84-8af9-d34dd48db174.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/3D\/91\/88cdf146-e105-4096-8eeb-b36645a1c4c6.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/DA\/CC\/fa45b36f-627e-408a-b04d-24d098302bad.JPG\"\u003e","brand":"Shopify","offers":[{"title":"Default Title","offer_id":14599426080812,"sku":"1311982","price":246.92,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/72de2609-532d-4382-97c9-78b4c4e3edb6.jpg?v=1582106246","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/dc-6v-to-30v-one-way-relay-module-delay-power-off-disconnection-trigger-delay-cycle-timer","provider":"Electronic Pro ","version":"1.0","type":"link"}