{"product_id":"ny-d02-100a-40a-double-pulse-encoder-spot-soldering-station-time-current-controller-control-board-adjustable-digital-display","title":"NY-D02 100A\/40A Double Pulse Encoder Spot Soldering Station Time Current Controller Control Board Adjustable Digital Display","description":"\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eThe main features of the controller:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. Welding pulse for a single and double pulse can be switched to use, anyone welding time is set to 0, can become a single pulse welding\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. With network voltage compensation, according to the changes in electricity, automatically adjust the output to ensure that the same parameters in the welding with the same heat to maintain the same, the solder joint\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. Parameter adjustment for the encoder input mode, more accurate and convenient\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. With the welding count function, counting range 0-999, so you do the welding \"heart\", and can be saved.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e5. Time input 0-100 cycles, unit cycle (1 cycle is 20ms) current input (300-999). The current adjustment step is 0.1% and the regulation is more subdivided. If there are other ranges required, you can customize it.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e6. 3 blue 0.56 inch digital tube, the size of the browser than the knob control version of the large, our knob knob digital tube is 0.36 inches.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e7. Onboard power, pedal, trigger, run, time, current, interval, time, current indicator, so that each state has a clear indication\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e8. The whole board using STM8 industrial microcontroller to do the main control core\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e9. Strong and weak through the optocoupler isolation, operation more secure.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e10. Power cord and foot switch line with screw-free terminal, more convenient and reliable\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e11. Design a reliable zero-crossing detection circuit to ensure that the SCR phase shift accurate\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e12. The controller is compatible with 100A-40A thyristor\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eWiring instructions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.1. Operation Indicator Indicator Description\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.2. Display status description:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThe controller has three kinds of operating status, welding preparation, parameter query, parameter change\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWelding preparation: running light is always bright, time, current, interval, time, current indicator off\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eParameter query: running indicator light off, time, current, interval, time, current corresponding to the amount of light, the digital tube is always bright, the value of the display for the corresponding parameter values\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eParameter change: Run indicator light off, time, current, interval, time, current corresponding to the amount of light, digital tube flashing, the value displayed for the corresponding parameter value change value.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.3. Welding preparation:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThrough the (Select \/ adjust) encoder counterclockwise rotation, so that the running light is always on, time, current, interval, time, current indicator light off, this time can be welded, digital tube display value for the current welding count\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.4. Voltage calibration:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eBecause the controller with a network pressure compensation function, so when the first installation, to carry out voltage calibration, just one can be calibrated. (As long as you do not replace the power transformer, you do not need to re-calibration)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eCalibration operation:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eIn the running state, long-press the micro-open until the time, current, interval lights all light, then use a multimeter to measure the mains voltage, such as the measured voltage of 225V, then, rotary encoder, the digital tube Display the value of 225 can be, and then double-click the microswitch, exit the calibration.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.5. Count is cleared\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eThe controller with a welding count function, in the operation of welding, each welding, welding count automatically increased by 1. Count range 0-999.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eIf you want to clear, in the running state, double-click the [enter \/ save] button, the count is automatically cleared.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage includes:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x Welder transformer controller \u003c\/span\u003e\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/9F\/B0\/41238a44-6e47-4796-80f6-8bccd9b0bd5f.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/E0\/E9\/9c63b07f-7b81-4e29-b599-a86ddea66280.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/AF\/9D\/d0021da5-2793-4e13-8b6f-9ddedf26b3fe.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/5E\/19\/52678da7-8bfc-4f63-98b7-5de2f214d96f.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/FA\/BF\/b9e562d2-8ccb-4139-9f54-8d0971363092.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/FA\/E9\/f8e30133-fb8e-4479-9c6d-ebb99aecf5f0.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/B2\/F0\/6ce9701e-41c7-45c3-add0-3241beb14532.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/9E\/3E\/cfd9dc4f-28d9-4e25-8d2e-743af379b89a.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/3D\/60\/a7dc48b9-5be6-466c-8a61-7ea958c26114.JPG\"\u003e","brand":"Electronic Pro","offers":[{"title":"40A","offer_id":35468057116828,"sku":"1571346","price":1009.95,"currency_code":"ZAR","in_stock":true},{"title":"100A","offer_id":35468057149596,"sku":"1571346","price":1300.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/9b3b8275-ba4b-44b3-b375-df860140321d.jpg?v=1597149261","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/ny-d02-100a-40a-double-pulse-encoder-spot-soldering-station-time-current-controller-control-board-adjustable-digital-display","provider":"Electronic Pro ","version":"1.0","type":"link"}