{"product_id":"turbidity-meter-tester-digital-concentration-meter-monitor-measurement-range-0-200ntu","title":"Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU","description":"\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: 14px;\"\u003eMicrocomputer configuration, with an average measurement mode, with data storage and query functions, automatic switching range.\u003c\/span\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eZD series intelligent turbidimeter using light scattering principle, the calibration solution using formazine standard solution commonly used international. The utility model is a precise and intelligent instrument, which has the advantages of good linearity, accurate and reliable measurement and convenient operation.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eApplicable to tap water pl ant, water treatment plant, swimming pool water reuse, the food and beverage industry as the instrument. It is a necessary instrument for water laboratory.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eZD seriesIntelligent turbidimeter using light scattering principle, the calibration solution using formazine standard solution commonly used international. The utility model is a precise and intelligent instrument, which has the advantages of good linearity, accurate and reliable measurement and convenient operation.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eSpecification:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eDetermination principle: 90° scattered light\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eMinimum display (NTU)\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e0.1\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eMeasurement range (NTU)\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e0-200 \/ 0 ~1000\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eCalibration point\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e0NTU,100NTU \/ 0NTU,50NTU,100NTU,200NTU,400NTU,800NTU,1000NTU\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eIndication error\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e±8% (± 2.5%F.S)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eRepeatability\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e≤1%\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eZero drift\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e±1%F.S\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eInstrument weight\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e0.5KG\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003eOutline dimension\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e210\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e x \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e75\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e x \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e70MM\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003ePower supply\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003eDC 1.5V\u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e x \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e5 AA alkaline dry cell \/ AC 220V\/50Hz\/DC7.5V\/ 0.2A power adapter\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eMatters needing attention\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eZDA series of scattered light turbidity meter is a precision measuring instrument which is combined with photoelectric. It is necessary to read the instruction manual carefully before operation and get accurate measurement results.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1, the use of the environment must meet the working conditions.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2, the measurement tank must be clean and dry for a long time, no dust, no need to cover the cover.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3, humid climate, must be extended to boot time.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e4, the solution should be carefully poured into the sample bottle, to prevent the formation of bubbles, affecting the accuracy of measurement.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e5, replace the sample bottle or after repair must be re calibration.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e6, non professional maintenance engineer, do not open the instrument for maintenance.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eWorking conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. The instrument should be placed in the drying room, use temperature of 5 DEG C - 35.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. When used, should be placed on the flat surface, and avoid vibration.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. Indoor lighting should not be too strong, and avoid direct sunlight irradiation.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e4. Try to keep away from the high intensity magnetic field, electric field and high frequency electric equipment.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. Avoid high temperature close to the instrument.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e6. The power supply of the instrument: 220V± 22V, 50± 1Hz, and must have a good grounding wire.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eMeasurement preparation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1, open the instrument power switch;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2, do not fall wool soft cloth to wipe the water stain on the sample bottle and fingerprints, such as not easy to clean the cleaning agent can be soaked, and then rinse with water clean;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3, ready for school pocket zero turbidity water and preparing for the calibration of formazine turbidity standard solution\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e4, with a clean container to collect a representative sample;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperation steps(see Appendix flow chart)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMeasurement solutionturbidityThe instrument must be calibrated before.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1 Correction\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eBoot into the main interface menu window,“ switching ” key select “ correction ” option.At this time the instrument display into0000NTU turbidity liquid, open the machine above the sliding cover panel,Will be installedYesZero turbidity waterSample bottleMeasurement pool,Cover with sliding coverTo be stabilized by “ confirm ” key. In order to put in the correct solution. Press “ confirm ” key end. Enter the main menu option. Or press “ switch ” key forced exit, exit to save the corrected data. Enter the main menu interface.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eNote: every time to wipe cleanSample bottle wallTraces of water and fingerprints,Should not leave any traces, so as not to affect the measurement accuracy. every timeSample bottleThe direction and the position of the measuring pool are as consistent as possible.Please use the same sample bottle when comparing and measuring, so as to reduce the inaccuracy of the data value caused by the error of the sample bottle.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2,turbidity measure\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMain interface menu window,By “ switch ” key select “ measure ” option.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eWill be measuredsamplePour cleanSample bottleIn, will be installedYesTo be measuredsampleSample bottleMeasurement pool,Cover with sliding cover,The numerical display is the instrument to be checked.Turbidity value.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3,ProtectDeposit,extractUsage method\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn the measurement process, the measurement can be carried outPreservation. Press“ save ”Key can be stored up to10 sets of data. Sign outPreservationPress“confirm”Key, back to the status of the measurement.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003ePreservationData can be queried. Press“ extraction ”Key can. Sign outextractPress“confirm”Key, back to the status of the measurement.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003ePackage included:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: 14px;\"\u003e1 x Digital Concentration Meter\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eDetails pictures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/FC\/38\/28768094-5d25-48f1-8fc7-20c91fefa14d.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/99\/3B\/e9e1823b-815e-45e6-8a91-0b08d24cb9eb.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/E1\/E7\/aee9a792-ae7e-4c4f-9ec9-68279f60f8ab.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/BC\/EC\/9d782137-0023-4ede-bcbd-fa987a89f0e2.jpg\"\u003e","brand":"Shopify","offers":[{"title":"Default Title","offer_id":29606133039148,"sku":"1449906","price":10845.65,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/28768094-5d25-48f1-8fc7-20c91fefa14d_d7f42055-8def-4a05-8f28-e65c3d13a54f.jpg?v=1583829428","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/turbidity-meter-tester-digital-concentration-meter-monitor-measurement-range-0-200ntu","provider":"Electronic Pro ","version":"1.0","type":"link"}