{"product_id":"unv-gsm-2c-sms-call-controller-remote-control-switch-for-pump-control-cabinet-server-restart","title":"UNV-GSM-2C-SMS\u0026CALL Controller Remote Control Switch For Pump Control Cabinet Server Restart","description":"\u003cdiv\u003e\n\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eInstructions: \u003c\/strong\u003e\u003c\/span\u003e\u003ca href=\"http:\/\/img.staticbg.com\/file\/products\/20180919032052SMS-Relay-controller-TWO-Channel-V1.1.pdf\" target=\"_blank\"\u003e\u003cspan style=\"font-size:14px;\"\u003ehttp:\/\/img.staticbg.com\/file\/products\/20180919032052SMS-Relay-controller-TWO-Channel-V1.1.pdf\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eHardware description:\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePower: Power voltage: 9V-36V. When using 9V power supply, the current must be guaranteed 1.0A or above.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRelay interface: Using 250V 10A relay.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSIM Card Socket: Insert MICRO SIM card when system powered off. \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eLED interface: D3 D6 D7 (D7 is close to the positioning hole, D6 is close to the antenna interface)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eSMS command instructions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAuthorized number configuration: This system supports up to 3 authorization numbers. Format:*code*#NAuthorized number#, after setup successfully, the device will reply. For example, if system code is 123456, and you want to set the first authorized number is 18846919911, the command:*123456*#118846919911#.the device will reply: User1 Number: 18846919911 Set OK. And you want to set the second authorized number is 18846919900, you can send: *123456*#218846919900#.the device will reply, content is: User2 Number: 18846919900 is set ok! The new authorization number is saved in the device.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eCode configuration: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eFormat: *6 old code**6 new code*. After setup successfully, the device will reply. For example, if system code is 123456, you want to revise the new code is 666666, send the SMS:*123456**666666*. The device will reply: SYS Code: 666666 Set OK. The new code is saved in the device.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eRelay control command:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRelay1 On command: ON1; Relay2 On command: ON2;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRelay1 Off: OFF1; Relay2 Off: OFF2; \u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRelay1 on for only 1-2 second: STH1, Relay2 on for only 1-2 second: STH2.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSystem status query instruction: STA.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eUse process:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInsert SIM card\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eConnect the controlled equipment\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInterventional power supply\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWaiting for equipment to start ready\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eChange the Authorization number (if the device does not have the correct number)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSend command to control relay state\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage includes:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x UNV-GSM-2C-SMS\u0026amp;CALL controller\u003c\/span\u003e\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/C4\/11\/07c39aec-e2e5-4ce3-a7d4-b1fc4af37746.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/71\/83\/2e147073-c1ce-40b8-b947-d9203a2de484.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/74\/D0\/328d8cc1-6f78-46a2-9ee6-134ac9f13af4.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/BC\/73\/a4fa48b4-9393-41ab-8aab-2ee15c73d139.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/F9\/2D\/c209653a-d33a-4d8e-b50a-9e4bf9659e82.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/13\/04\/4199c863-5988-4249-8bdd-b8840993247d.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/D0\/86\/dc6c99e9-5cb2-4caa-a456-4e0df3336b16.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/A9\/03\/bf012b77-89bc-4dd1-910c-23c46ddd2b13.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/img.staticbg.com\/images\/oaupload\/banggood\/images\/AE\/CD\/6de0f6e4-b2e9-496a-8f77-54c78919dfeb.JPG\"\u003e","brand":"Shopify","offers":[{"title":"Default Title","offer_id":14009205325868,"sku":"1354007","price":913.48,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/127582d4-1365-4265-95e8-fc33c6080032_78f0ca88-7e58-49c1-a7e8-f68cd2d2b57a.jpg?v=1587025970","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/unv-gsm-2c-sms-call-controller-remote-control-switch-for-pump-control-cabinet-server-restart","provider":"Electronic Pro ","version":"1.0","type":"link"}