{"product_id":"xh-m453-dual-digital-display-temperature-humidity-controller-thermostat-humidity-smart-thermostat-incubator-control-ac-220v","title":"XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V","description":"\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eProduct model: XH-M453\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eProduct specifications: DC12~24V\/AC220V\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eTemperature range: -20~60°C\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eHumidity range: 0~100%RH\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eControl accuracy: ±0.1 °C \/ 0.2%\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eDetection probe: integrated sensor\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eOutput type: relay output\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eOutput capacity: up to 10A\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eProduct weight: about 150g\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eAppearance size: 105*75*38mm\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eEmbedded hole: 81*57mm\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePackage Included:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e1 x XH-M453 Dual Digital Display Temperature Humidity Controller\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e1 x Sensor Cable\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eUser Manal:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e1. Connect the power supply and temperature control humidity equipment correctly according to the wiring diagram. Pay attention to the temperature control and humidity control equipment. Do not connect the wrong ones. When connecting the DC12~24V power supply, distinguish the positive and negative poles. AC220V does not divide the zero fire line.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e2. Stop the temperature setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress the SET button. When the red screen number starts to flash, press the up and down buttons to adjust the desired stop temperature. After setting, wait for 10 seconds without waiting for the system to automatically save the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e3. Heating or cooling mode setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress and hold the up key, when the red screen displays C-0, press the setting button to enter the C-0 mode setting.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eThe down button switches between blue screens L and H, where L stands for heating and H stands for cooling. (Note: L when you pick up\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eThe temperature-controlled load must be a heating device. When H, the load you connect must be a cooling device. ) set well\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eWait 10 seconds, the system automatically saves the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e4. Temperature difference setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e  Press and hold the up key, when the red screen displays C-0, press the up and down keys to switch to the C-1 temperature difference setting, and then press\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eSet the temperature to the temperature difference setting, then press the up and down keys to adjust the temperature difference you want; set\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eWait 10 seconds, the system automatically saves the data. (If the stop temperature is set to 35 ° C, the mode is set to L plus\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eIn the hot mode, the temperature difference is set to 5, and the starting temperature is 35-5=30°C, and the temperature control range is between 30~35°C.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eOn the contrary, if the mode is set to H cooling mode, the starting temperature is 35+5=40°C, and the temperature control range is\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eBetween 35~40°C)\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e5. Temperature calibration\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress and hold the up key, when the red screen displays C-0, press the up and down keys to switch to the C-2 temperature correction mode, press the set key to enter the calibration mode, and then press the up and down keys to adjust the difference you want. Value; if the actual temperature is 28 ° C, the probe detection temperature is 28.2 ° C, then the correction difference is set to -0.2; if the detection temperature is low, the correction difference can be increased. Wait 10 seconds after setting, the system automatically saves the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eTemperature parameter code table:\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eCode    Name Setting range                                  Default parameters\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eC-0       mode setting L heating H cooling             L heating mode\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eC-1       temperature difference 0.1~50°                C 2.0°C\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eC-2       temperature calibration -10 and 10 °C      0.0 °C\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e6. Stop the temperature setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e   Press the SET button, the red screen number starts to flash, and then press the SET button to switch to the blue screen number.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eBlink, press the up and down keys to adjust the desired stop humidity value; do not wait after setting 10\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eIn seconds, the system automatically saves the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e7. Humidification or dehumidification mode setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e   Press and hold the key, when the red screen displays H-0, press the setting button to enter the H-0 mode setting.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eThe down button performs switching between blue screens L and H, L for humidification and H for dehumidification. (Note: L when you pick up\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eThe humidity control load must be a humidification device. When H is used, the load you are connected to must be a dehumidification device. ) set well\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eWait 10 seconds, the system automatically saves the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e8. Humidity difference setting\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress and hold the key, when the red screen displays H-0, press the up and down keys to switch to the H-1 humidity difference setting, press\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress the setting button to enter the humidity difference setting, press the up and down keys to adjust the setting you want, and set it.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eWait 10 seconds, the system automatically saves the data. (If the stop humidity is set to 50% RH, the mode is set to L plus\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eIn wet mode, the humidity difference is set to 5% RH, the starting humidity is 50-5=45%RH, and the humidity control range is between 45~50%RH. On the contrary, if the mode is set to H dehumidification mode, the starting humidity is 50+. 5=55% RH, the humidity control range is between 50~55% RH)\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e9. Temperature calibration\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress and hold the key, when the red screen displays H-0, press the up and down keys to switch to the H-2 humidity correction mode.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePress the setting button to enter the calibration mode, press the up and down keys to adjust the setting difference; if the actual humidity is 56% RH,\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eThe probe detects a humidity of 56.2% RH, and the correction difference is set to -0.2;\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eLow, just adjust the correction difference. Wait 10 seconds after setting, the system automatically saves the data.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eHumidity parameter code table\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eCode             Name Setting range                                                       Default parameters\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eH-0               mode setting L humidification H dehumidification        L humidification mode\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eH-1               Humidity difference 0.1~50%RH                                    10%RH\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eH-2               Humidity Calibration -10 and 10%RH                             0.0%RH\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e10. Restore factory settings\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e   Press and hold the up and down keys for 5 seconds at the same time. When the screen displays 888, the factory will be restored.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"imgBox\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"bg_lazy\" title=\"XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V \/ DC12-24V\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/F1\/2E\/47246439-5d36-4452-980f-0a24a05d678a.jpg.webp\" data-original=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/F1\/2E\/47246439-5d36-4452-980f-0a24a05d678a.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/F1\/2E\/47246439-5d36-4452-980f-0a24a05d678a.jpg.webp\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"bg_lazy\" title=\"XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V \/ DC12-24V\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/2C\/CF\/fb0fb3be-313c-4cfb-a70d-61e45dc7ad1c.jpg.webp\" data-original=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/2C\/CF\/fb0fb3be-313c-4cfb-a70d-61e45dc7ad1c.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/2C\/CF\/fb0fb3be-313c-4cfb-a70d-61e45dc7ad1c.jpg.webp\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"bg_lazy\" title=\"XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V \/ DC12-24V\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A5\/9A\/fe5f337a-b9ab-4cb6-9db4-b0dfe78488eb.jpg.webp\" data-original=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A5\/9A\/fe5f337a-b9ab-4cb6-9db4-b0dfe78488eb.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A5\/9A\/fe5f337a-b9ab-4cb6-9db4-b0dfe78488eb.jpg.webp\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"bg_lazy\" title=\"XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V \/ DC12-24V\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A0\/26\/690bb88b-de94-41ab-a287-bf30e0deb00b.jpg.webp\" data-original=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A0\/26\/690bb88b-de94-41ab-a287-bf30e0deb00b.jpg\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/banggood\/images\/A0\/26\/690bb88b-de94-41ab-a287-bf30e0deb00b.jpg.webp\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Shopify","offers":[{"title":"Default Title","offer_id":40068700930243,"sku":"","price":739.98,"currency_code":"ZAR","in_stock":true}],"url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/xh-m453-dual-digital-display-temperature-humidity-controller-thermostat-humidity-smart-thermostat-incubator-control-ac-220v","provider":"Electronic Pro ","version":"1.0","type":"link"}