{"product_id":"xh-w1818-high-precision-microcomputer-temperature-controller-circular-digital-display-embedded-thermostat","title":"XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded Thermostat","description":"\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eProduct Name: High precision microcomputer temperature controller\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eProduct model: XH-W1818\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTemperature range: -50~110°C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eResolution: 0.1 ° C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTemperature control range: -50~110°C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTemperature control accuracy: 1 ° C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTemperature probe: NTC10K (B3950) L=1M\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSupply voltage: DC12V\/DC24V\/AC220V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eApplicable environment: -25~55°C Humidity 50%-85%\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOutput type: 10A relay output\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAppearance size: diameter 80mm\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eOpening size: diameter 61mm\/3mm\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eHow to use:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eSetting function description:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003ePress SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"162\" style=\"width: 571px;\" width=\"571\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px; width: 72px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eCode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 243px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eCode description\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSetting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eFactory setting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eC\/H\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eBacklash setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e0.1-30\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:num=\"2\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSet upper limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eMax. 110 ° C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e110°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eSet lower limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eMin. -50 ° C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e -50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eTemperature correction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e -10~10°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e0°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eDelayed start\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e0-10 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:num=\"0\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eHigh temperature alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e -50~110°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e110°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"height: 18px;\" x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP7\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eData lock\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eOFF\/ON\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd x:str=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP0: Heating and cooling mode H\/C\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eThe low temperature start is the heating mode, set to H. For example: the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eThe high temperature start is the cooling mode, set to C. For example: the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP1: Hysteresis setting\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn heating mode (H): The measured value starts the output heating to the set value when the set value - hysteresis.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature - low temperature = hysteresis, 38-36 = 2)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn cooling mode (C): When the measured value \u0026gt;= set value + hysteresis, the output cooling is started until the set value stops.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature - low temperature = hysteresis, 26-24 = 2)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP2: Limit the maximum set value (non-temperature control setting): up to 110 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP3: Limit the min. set value (non-temperature control setting): min. -50 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP4: Temperature correction\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eWhen the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFor example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP5: Delay start time: 0~10 minutes\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eWhen controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP6: High temperature alarm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eWhen the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP7: Data lock function\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eTurn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage includes:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x High precision microcomputer temperature controller\u003c\/span\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/A3\/1D\/63530218-9d0a-4408-91f7-dec87005b09f.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/21\/D2\/aff8795c-b765-4a7e-b139-2b971311ff51.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/D7\/D8\/79f5203d-6aed-4330-9426-5659ba4bd8d3.jpg\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/B2\/83\/a2871dd3-2d92-4fdf-af91-14911e68e353.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/FE\/92\/bb470a32-cfa1-4be0-9671-604c9b6f6524.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/15\/69\/5087f597-dde8-4373-b4c3-b997c35b2441.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/0B\/C8\/ccdea81d-5328-4577-97f3-5bbdb4217878.JPG\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/1B\/0E\/b8393179-fe67-44f4-9596-58086f1caa9b.JPG\"\u003e","brand":"Electronic Pro","offers":[{"title":"110V~220V","offer_id":35551821070492,"sku":"1590312","price":580.0,"currency_code":"ZAR","in_stock":true},{"title":"DC12V","offer_id":35551821103260,"sku":"1590312","price":427.98,"currency_code":"ZAR","in_stock":true},{"title":"DC24V","offer_id":35551821136028,"sku":"1590312","price":427.98,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/2a94626b-4442-4558-b376-97f6449264a5.jpg?v=1597576053","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/xh-w1818-high-precision-microcomputer-temperature-controller-circular-digital-display-embedded-thermostat","provider":"Electronic Pro ","version":"1.0","type":"link"}