{"product_id":"xy-dj01-dc6-30v-digital-display-one-way-relay-module-delay-power-off-disconnect-trigger-delay-cycle-timing-circuit-switch","title":"XY-DJ01 DC6-30V Digital Display One-way Relay Module Delay Power Off Disconnect Trigger Delay Cycle Timing Circuit Switch","description":"\u003cdiv id=\"specification\"\u003e\u003c\/div\u003e\u003cdiv id=\"specification_end\"\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 18px;\"\u003e\u003cb\u003eDescription:\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003eRelay module delay power off and trigger delay cycle timing circuit switch\u003c\/font\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eTiming range: 0.01 second to 9999 minutes The liquid crystal display of this product is very clear, easy to use, and powerful, but please read the operating instructions of this product in detail. It is a very practical product.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cb\u003eProduct Highlights:\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003e1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;\u003c\/font\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003e2. Support button trigger control, high and low level trigger, switch value control, support NPN, PNP sensor access, suitable for most occasions;\u003c\/font\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003e3. Wide voltage supply (6~30V), \u003c\/font\u003eRail installation, very convenient to use;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003e4. There is a key pause function, with reverse connection protection, reverse connection does not burn;\u003c\/font\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. Added sleep mode. After enabling, without any operation for about 5 minutes, the LCD backlight will be automatically turned off; any key to wake up;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e6. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e7. All set parameters are automatically saved after power-off.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cb\u003eOperating mode:\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP0：After the signal is triggered, the relay is turned on for OP time, and then off; within the OP time, the signal is triggered again invalid\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP1: After the signal is triggered, the relay is turned on for OP time and then off; within the OP time, the signal is triggered again to re-timing\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP2：After the signal is triggered, the relay is turned on for OP time and then turned off; within the OP time, the signal triggers reset again, the relay is turned off, and the timing stops\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP3:\u003cspan style=\"white-space:pre\"\u003e\u003c\/span\u003eAfter the signal is triggered, the relay is turned off for CL time, and then the relay is turned on; \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP4：After the trigger signal is given, the relay is turned on for OP time, the relay is disconnected for CL time, and then the above actions are cycled, the signal is given again in the cycle, the initial state is restored, and the timing is stopped; the number of cycles (LOP) can be set; the cycle ends, keep the relay off ;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP5: Give the trigger signal, after the relay is disconnected from the CL time, the relay will be turned on for OP time, and then cycle the above actions, give the signal again in the cycle, restore the initial state, and stop timing; the number of cycles (LOP) can be set; the cycle ends, keep the relay on ;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP6：After power-on, no trigger signal is needed, the relay is on for OP time, the relay is off for CL time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle is over, keep the relay off;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP7：There is no need to trigger signal after power-on, the relay is off CL time, the relay is on OP time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle ends and the relay is kept on;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP8：Signal hold function If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing OP; during the timing, there is a signal again, and the timer is clearï¼?\/span\u0026gt;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eP9：Signal hold function If there is a trigger signal, the timer is cleared and the relay remains off; when the signal disappears, the relay is turned on after timing CL; during the timing, there is another signal, and the timer is clearedï¼?\/span\u0026gt;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003e(P0~P7) mode\u003c\/font\u003e, short press the \u003cfont color=\"#ff0000\"\u003epause\u003c\/font\u003e button, when the system does not trigger the timing, the system starts timing; when the system is already timing, the system pauses timing, the relay is disconnected, and flashes 'OUT' as a reminder;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cfont color=\"#ff0000\"\u003eIn P8 P9 mode\u003c\/font\u003e, the \u003cfont color=\"#ff0000\"\u003epause button\u003c\/font\u003e on the running interface is used as the trigger signal, and its button function is disabled by \u003cfont color=\"#ff0000\"\u003eshort press\/long press\u003c\/font\u003e;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\u003cb\u003eProduct parameter:\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e1: Working voltage: 6-30V power supply\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e3: Output capacity: can control equipment within DC 30v 30A or AC 220v 30A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e4: Quiescent current: 15mA Working current: 50-130mA\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e5: Service life: more than 100,000 times; working temperature: -40-85??\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters are always remembered after power failure.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eTiming range\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cfont color=\"#ff0000\"\u003e0.01 second (minimum) ~ 9999 minutes (maximum) continuously adjustable          \u003c\/font\u003e                                         \u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eHow to choose the timing rangeï¼?\/div\u0026gt;\u003cdiv style=\"font-size: 14px;\"\u003eIn the OP\/CL parameter modification interface, short press the pause button to select the timing rangeï¼?\/div\u0026gt;\u003cdiv style=\"font-size: 14px;\"\u003eXXXX  No decimal point, timing range \u003cfont color=\"#ff0000\"\u003e1 second~9999 seconds\u003c\/font\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eXXX.X The decimal point is in the tenth place, and the timing range is \u003cfont color=\"#ff0000\"\u003e0.1 seconds to 999.9 seconds\u003c\/font\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eXX.XX The decimal point is in hundreds, and the timing range \u003cfont color=\"#ff0000\"\u003e0.01 seconds to 99.99 seconds\u003c\/font\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eX.X.X.X All decimal points are lit, timing range \u003cfont color=\"#ff0000\"\u003e1 minute to 9999 minutes\u003c\/font\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eFor example, if you want to set the OP to 3.2 seconds, move the decimal point to the tens place, and the LCD will display 003.2\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eParameter description: OP on time, CL off time, LOP cycle times (1??999 times, '----' represents infinite cycles)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cb\u003eParameter settings\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ea) Enter the setting interface by long pressing the setting buttonï¼?\/span\u0026gt;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eb) First set the work mode, the work mode flashes to remind, short press the increase\/decrease button to set the work mode;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ec) Short press the setting button, select the working mode, and enter the system parameter setting;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ed) In the system parameter setting interface, short press the setting button to switch the system parameter to be modified, and short press\/long press the increase\/decrease button to modify;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e(Note: Short press the setting button is invalid in P0~P3\/P8\/P9 mode);\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ee) In the OP\/CL parameter modification interface, short press the pause button to switch the timing unit (1s\/0.1s\/0.01s\/1min)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ef) After setting all parameters, long press the setting button to save the parameter setting and exit the setting interfaceï¼?nbsp;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. Additional functions\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ea) Automatic sleep function: In the running interface (P0~P7 mode), long press the pause button to start or close the automatic sleep function (LP selects on to start the sleep function, about five minutes, without any operation, the LCD backlight automatically turns off , The system is running normally, any key is pressed to wake up; off is to close the sleep function);\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003eb) Parameter view: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003ec) Display content switching: In P4 ~ P7 mode, short press the DOWN key to switch the display content (operating time\/cycle times);\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 18px; font-weight: 700;\"\u003ePackage includes:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 18px; font-weight: 700;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1 x Relay Module\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 18px; font-weight: 700;\"\u003eDetails pictures: \u003c\/span\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/3F\/54\/1dfc81f2-5eb4-40e9-9166-e5b14d1bc201.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/3E\/8D\/c4bbb9bf-a3c3-4b94-801c-7fef4545f4c3.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/76\/D0\/e5dd0ff3-f720-44fa-89dd-eaf64587b059.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/43\/B7\/2492d80a-f9c9-4237-ae0a-9f59975e88b5.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/04\/69\/9aa11e61-a03d-4a86-baed-71b631cfcf02.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/imgmgr.banggood.com\/images\/oaupload\/banggood\/images\/7F\/E4\/58a56425-b40b-4e00-a20c-1493e5caeb2a.jpg\" style=\"width:1000px\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronic Pro","offers":[{"title":"Default Title","offer_id":37882863157443,"sku":"1785080","price":446.94,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/ea3ea947-b7fa-4e9a-9054-f7db8c54caaf.jpg?v=1609950997","url":"https:\/\/electronic-pro-south-africa.myshopify.com\/products\/xy-dj01-dc6-30v-digital-display-one-way-relay-module-delay-power-off-disconnect-trigger-delay-cycle-timing-circuit-switch","provider":"Electronic Pro ","version":"1.0","type":"link"}